| Home > Products > Chemicals & Paint > MSDS Sheets > MSDS 9112 -- [Back] | |||
|
MSDS 9112 9112: Flange Sealant 50 Ml [4]MSDS Last updated: 01/08/2010
Permatex, Inc.
10 Columbus Blvd.
Hartford, CT 06106 USA
Telephone: 1-87-Permatex
(877) 376-2839
Emergency: 800-255-3924
International Emergency: +01- 813-248-0585
Material Safety Data Sheet
1. PRODUCT IDENTIFICATION
Product Name: ANAEROBIC FLANGE SEALANT 50ML
Item No: 51531
Product Type: Anaerobic
2. HAZARDS IDENTIFICATION
Component Weight% ACGIH TLV:TWA OSHA PEL:
POLYURETHANE METHACRYLATE 50-70 Not listed Not Listed
RESIN
MIXTURE
POLYGLYCOL DIMETHACRYLATE 10-30 Not Listed Not Listed
25852-47-5
TREATED SILICON DIOXIDE, <10 10 mg/m3 10 mg/m3 total
SYNTHETIC, dust
CRYSTALLINE-FREE
67762-90-7
ACRYLIC ACID <5 2 ppm 10 ppm TWA; 30
79-10-7 mg/m3 TWA
2-HYDROXYETHYL <5 Not Listed Not Listed
METHACRYLATE
868-77-9
DIMETHYLBENZYL <3 Not listed Not Listed
HYDROPEROXIDE
80-15-9
3. HAZARDS IDENTIFICATION
Toxicity: May cause eye, skin irritation.
Ingestion may irritate
digestive tract and cause
nausea, vomiting and diarrhea.
May cause skin sensitization.
Note: this product does not
contain microcrystalline
silica.
Primary Routes of Entry: Eye and skin contact,
ingestion, inhalation
Signs and Symptoms of Exposure: May cause redness to eyes and
irritation to nasal passages.
Repeated skin contact may cause
allergic skin reactions
Component Weight% NTP ACGIH IARC
Carcinogens
ACRYLIC ACID <5 A4-Not Group 3
79-10-7 Classifiable Monograph
as a Human 71, 1999;
Carcinogen Supplement
7, 1987;
Monograph
19, 1979
Medical Conditions Recognized as Being May aggravate preexisting dermatitis
Aggravated by Exposure:
4. FIRST AID MEASURES
Ingestion: If swallowed, DO NOT induce
vomiting. Keep individual calm.
Obtain medical attention.
Inhalation: Move to fresh air in case of
accidental inhalation of
vapours. Obtain medical
attention.
Skin Contact: Wash off with soap and water. If
skin irritation persists, call a
physician.
Eye Contact: In case of contact, immediately
flush eyes with plenty of water
for at least 15 minutes and get
medical attention if irritation
persists.
5. FIRE FIGHTING MEASURES
Flash Point (F/C): >200F TCC
Recommended Extinguishing Media: Water fog, carbon dioxide, foam,
dry chemical.
Special Fire-Fighting Procedures: Firefighter should wear
self-contained breathing
apparatus.
Hazardous Products of Combustion: Irritating vapors, Oxides of
carbon
Unusual Fire/Explosion Hazards: None
Lower Explosive Limit: 2.0: Acrylic acid
Upper Explosive Limit: 8.0: Acrylic acid
6. ACCIDENTAL RELEASE MEASURES
Spill Procedures: Maintain good ventilation. Take
up with an inert absorbent.
Store in a closed waste
container until disposal.
7. HANDLING AND STORAGE
Storage: Store below 100 degrees F. Keep
in cool and dark place. Avoid
direct sunlight.
Handling: Avoid prolonged skin contact.
Keep away from eyes. Do not
inhale vapors.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Eyes: Safety glasses
Skin: Neoprene or nitrile gloves
recommended
Ventilation: General; local exhaust
ventilation as necessary to
control any air contaminants to
within their exposure limits (or
to the lowest feasible levels
when limits have not been
established) during the use of
this product.
Respiratory Protection: Not required under normal use.
An approved organic vapor should
be worn when exposures are
expected to exceed applicable
limits.
9. PHYSICAL AND CHEMICAL PROPERTIES
Appearance: Purple gel
Odor: Irritating
Boiling Point: >150C
pH: Does not apply
Solubility in Water: Slight
Specific Gravity: 1.1@80F
VOC Content (Wt. %): 1.5%
Vapor Pressure <5 mmHg @25C
Vapor Density (Air=1): Heavier than air
Evaporation Rate: Not Determined
10. STABILITY AND REACTIVITY
Chemical Stability: Stable at normal conditions
Hazardous Polymerization: WILL NOT OCCUR.
Incompatibilities: Metal salts, heat and amines.
Conditions to Avoid: Heat
Hazardous Products of Combustion: Irritating vapors, Oxides of
carbon
11. TOXICOLOGICAL INFORMATION
See Section 3
12. ECOLOGICAL INFORMATION
No data available
13. DISPOSAL CONSIDERATIONS
Recommended Method of Disposal: Disposal should be made in
accordance with federal, state
and local regulations.
US EPA Waste Number: NH-Not a RCRA Hazardous Waste
Material
14. TRANSPORTATION INFORMATION
DOT (49CFR 172)
Domestic Ground Transport
DOT Shipping Name: Unrestricted
Hazard Class: None
UN/ID Number: None
IATA
Proper Shipping Name: Not regulated
Class or Division: None
UN/NA Number: None
IMDG
Proper Shipping: Unrestricted
Hazard Class: None
UN Number: None
Marine Pollutant: None
15. REGULATORY INFORMATION
SARA 313 Chemicals: The following component(s) is listed as a SARA
Section 313 Toxic Chemical.
ACRYLIC ACID, DIMETHYLBENZYL HYDROPEROXIDE
CALIFORNIA PROP 65:
No California Prop 65 chemicals are known to be present at or above the
No Significant Risk Level.
TSCA Inventory Status:
Listed on Inventory: YES All components of this product are listed (or
exempt) on the EPA TSCA inventory.
16. OTHER INFORMAITON
Estimated NFPA Rating: HEALTH 2, FLAMMABILITY 1, REACTIVITY 1
Estimated HMIS HEALTH 2, FLAMMABILITY 1, PHYSICAL HAZARD 0
Classification:
NFPA is a registered trademark of the National Fire Protection Assn.
HMIS is a registered trademark of the National Paint and Coatings Assn.
Prepared By: Denise Boyd, Health Revision Date:
and Safety Manager August/08/2007
Company: Permatex. Inc. 10 Revision Number: 2
Columbus Blvd.
Hartford, CT USA
06106
Telephone No.: 1-87-Permatex (877) 376-2839
The information contained in this MSDS was obtained from current and reliable sources, however, the data is provided without any warrenty, expressed or implied, regarding its correctness or accuracy. Since the conditions or handling, storage and disposal of this product are beyond the control of Imperial Supplies LLC, Imperial will not be responsible for loss, injury, or expense arising out of the products improper use. No warranty, expressed or inferred, regarding the product described in this MSDS shall be created or inferred by any statement in this MSDS. Various government agencies may have specific regulations regarding the transportation, handling, storage, use, or disposal of this product which may not be covered by this MSDS. The user is responsible for full compliance. For more product information by email, click here Imperial Supplies LLC does not provide services and products outside the United States |