| Home > Products > Chemicals & Paint > MSDS Sheets > MSDS 4212 -- [Back] | |||
|
MSDS 4212 4212: Hand Cleaner/Citrus 1 Gal [4]MSDS Last updated: 05/14/2007
Permatex, Inc.
10 Columbus Blvd.
Hartford, CT 06106 USA
Telephone: 1-87-Permatex
(877) 376-2839
Emergency: 800-255-3924
International Emergency: 813-248-0585
MATERIAL SAFETY DATA SHEET
1. PRODUCT IDENTIFICATION
--------------------------------------------------------------------------------
Product Name: FAST ORANGE PUMICE LOTION 1GA PMPBO
Item No: 25218
Product Type: Waterless hand cleaner.
2. COMPOSITION/INFORMATION ON INGREDIENTS
--------------------------------------------------------------------------------
Ingredient Weight Percent ACGIH TLV: OSHA PEL:
Water 75-85 Not Listed Not Listed
7732-18-5
Pumice 5-15 10mg/m3 (inhal) 15mg/m3 (total)
1332-09-8 3mg/m3 (resp) 5mg/m3 (resp)
D-Limonene 5-15 Not Listed Not Listed
5989-27-5
Ethoxylated 1-10 Not Listed Not Listed
C11-C16 Alcohol
127036-24-2
Silica, Quartz 0.1-1.0 0.05mg/m3 0.1mg/m3
14808-60-7 TWA respirable TWA respirable
3. HAZARDS IDENTIFICATION
--------------------------------------------------------------------------------
Toxicity: Oral LD50 greater than 5000 mg/kg. Primary irritation tests show
that this product is not a primary irritant.
Note: this product does not contain microcyrastalline silica.
Primary Routes of Entry: Eye and skin contact, ingestion, inhalation.
Signs and Symptoms of Exposure: None under normal conditions of use.
Ingredient Weight NTP ACGIH IARC
Percent Carcinogens
D-Limonene 5-15 male rat-clear Group 3 Monograph
5989-27-5 evidence: female 73: 1999
Rat-no evidence:
Male mice-no evidence:
Female mice-no
Evidence.
Silica, Quartz 0.1-1.0 A2-Suspected Group 1: Monograph
14808-60-7 Human 68: 1997 (inhaled)
Carcinogen
Medical Conditions Recognized as None known.
Being Aggravated by Exposure:
4. FIRST AID MEASURES
--------------------------------------------------------------------------------
Ingestion: If swallowed, DO NOT induce vomiting. Keep individual calm.
Obtain medical attention.
Inhalation; Immediate medical attention is not required.
Skin Contact: Flush with copious amounts of water..
Eye Contact: In case of contact, immediately flush eyes with plenty of water for
at least 15 minutes and get medical attention if irritation persists.
5. FIRE FIGHTING MEASURES
--------------------------------------------------------------------------------
Flash Point (F/C): >200 F. Method: Setaflash Closed Cup
Recommended Extinguishing Media: Carbon dioxide, chemical powder.
Special Fire-Fighting Procedures: No special procedures.
Hazardous Products of Combustion: None anticipated.
Unusual Fire/Explosion Hazards: None.
Lower Explosive Limit: Not determined
Upper Explosive Limit: Not determined
6. ACCIDENTAL RELEASE MEASURES
--------------------------------------------------------------------------------
Spill Procedures: Rinse away with water or wipe up with a towel.
7. HANDLING AND STORAGE
--------------------------------------------------------------------------------
Storage: Hand cleaner should be stored at temperatures
Between 40 degrees F. and 100 degrees F.
Handling: Follow all general safety precautions.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
--------------------------------------------------------------------------------
Eyes: Not required.
Skin: Not required.
Ventilation: None reasonable foreseeable.
Respiratory Protection; Not required under normal use.
9. PHYSICAL AND CHEMICAL PROPERTIES
--------------------------------------------------------------------------------
Appearance: White lotion with pumice
Odor: Orange
Boiling Point: Not determined
pH: 6.0-7.7
Solubility in Water: SOLUBLE
Specific Gravity: 1.03
VOC Content (wt.%): 7.2 % by weight
Vapor Pressure: Not determined.
Vapor Density (Air=1): Not determined
Evaporation Rate: Not determined
10. STABILITY AND REACTIVITY
--------------------------------------------------------------------------------
Chemical Stability; Stable at normal conditions
Hazardous Polymerization: Will not occur.
Incompatibilities: None known
Conditions to Avoid: Freezing
Hazardous Products of Combustion: None anticipated
11. TOXICOLOGICAL INFORMATION
--------------------------------------------------------------------------------
See Section 3
12. ECOLOGICAL INFORMATION
--------------------------------------------------------------------------------
No data available
13. DISPOSAL CONSIDERATIONS
--------------------------------------------------------------------------------
Recommended Method of Disposal: Dispose of uncontaminated material through sewer
system with permission of the authority responsible
for that system.
US EPA Waste Number: NH - Not a RCRA Hazardous Waste Material
14. TRANSPORTATION INFORMATION
--------------------------------------------------------------------------------
DOT (49CFR 172)
Domestic Ground Transport
DOT Shipping Name: Unrestricted
Hazard Class: None
UN/ID Number: None
Marine Pollutant: None
IATA
Proper Shipping Name: Not regulated
Class or Division: None
UN/NA Number: None
IMDG
Proper Shipping: Unrestricted
Hazard Class: None
UN Number: None
15. REGULATORY INFORMATION
--------------------------------------------------------------------------------
SARA 313 Chemicals: The following component(s) is listed as a SARA Section 313
Toxic Chemical.
None
CALIFORNIA PROP 65:
No California Prop 65 chemicals are known to be present at or above the No
Significant Risk Level.
TSCA Inventory Status:
Listed on Inventory: YES All components of this product are listed (or exempt)
on the EPA TSCA inventory.
16. OTHER INFORMATION
--------------------------------------------------------------------------------
Estimated NFPA Rating: Health 1, Flammability1, Reactivity 0
Estimated HMIS Classification; Health 1, Flammability, Physical Hazard 0
NFPA is a registered trademark of the National Fire Protection Assn.
HMIS is a registered trademark of the National Paint and Coatings Assn.
Prepared By: Denise Boyd, Health and Safety Manager Revision Date: Nov./23/2005
Company: Permatex. Inc. 10 Columbus Blvd. Hartford, CT USA 06106 Revision 5
Number;
Telephone No.: 1-87-Permatex (877) 376-2839
The information contained in this MSDS was obtained from current and reliable sources, however, the data is provided without any warrenty, expressed or implied, regarding its correctness or accuracy. Since the conditions or handling, storage and disposal of this product are beyond the control of Imperial Supplies LLC, Imperial will not be responsible for loss, injury, or expense arising out of the products improper use. No warranty, expressed or inferred, regarding the product described in this MSDS shall be created or inferred by any statement in this MSDS. Various government agencies may have specific regulations regarding the transportation, handling, storage, use, or disposal of this product which may not be covered by this MSDS. The user is responsible for full compliance. For more product information by email, click here Imperial Supplies LLC does not provide services and products outside the United States |